RMAN-RWS-001 rev. B • RW Series Repair Procedures • 2-80 •
4. Using the Table below as a guide, plug in the cables from the Printer to the CPU
Board. Ensure all ZIF connectors for the at ex cables are locked.
CPU CONNECTIONS
CABLE CPU CONNECTOR
MOTOR CABLE J6
BAR SENSOR FLEX CABLE J2
GAP SENSOR FLEX CABLE J10
PRINTHEAD CABLE J5
5. Re-secure the CPU Board. Refer to Procedure RK17949-020 for more details.
6. Assemble the Upper Housing to the Printer, and secure it with the retained
hardware. At this time either the “D” rings, or the Carrying strap which was
supplied with the printer should be reassembled.
7. Reinstall the Battery Pack and perform a two-key reset to verify that the Printer
has been properly reassembled.
8. Perform the Unit Test procedure. Perform a complete unit test to ensure that
the sensor calibrations are still correct, and the motor is operating correctly.
Thetestprocedurecanonlybeperformedbycertiedpersonnelusingspecial
equipment and software.