Programming
Status Reporting Commands
02/11/2009 TTP 7020™/TTP 7030™ Technical Manual P1003636-001
Status Reporting Commands
See also Status Reporting on page 73.
A status enquiry results in response ACK (06h) if all sensors are clear, but NAK (15h) + code if
one or more sensors report fault condition.
Note • All status commands are immediate, that is they pass the print queue and is answered
directly.
ESC ENQ 001
Status Enquiry
1B 05 01 hex
27 5 1 decimal
Figure 21 • Error Codes
Error code Meaning
ACK OK (printer is operable)
NAK 01h Paper left in presenter module. Attempt to clear the paper path failed.*
*. From firmware version 3.00, the printer will retry three times (cut + clear presenter), when failing to clear the
presenter.
NAK 02h Cutter jammed
NAK 03h Out of paper
NAK 04h Printhead lifted
NAK 05h Paper-feed error. No paper detected in presenter although 10 cm has been
printed. Paper might be wound around the platen or, in some way, has
been forced above the presenter module.
NAK 06h Temperature error. The printhead temperature has exceeded the 60 °C
maximum limit.
NAK 07h Presenter not running (no feedback from code wheel)
NAK 0Ah Black mark not found
NAK 0Bh Black mark calibration error
NAK 0Ch Index error
NAK 0Dh Checksum error
NAK 0Eh Wrong firmware type or target for firmware loading
NAK 0Fh Firmware cannot start because no firmware is loaded or firmware
checksum is wrong.
NAK 10h Waste bin timed out. If the customer doesn’t take the paper and the
printer clears the presenter due to a timeout, the pending error bit is set
and error code NAK 16 is reported.
NAK FFh Undefined error