Programming
System Related Commands
60
P1003636-001 TTP 7020™/TTP 7030™ Technical Manual 02/11/2009
A number of bytes in the flash PROM hold various parameter values called default
parameters. One or several of them can be overridden temporarily with this command.
See Default Parameter Settings on page 74.
The permanently stored parameters will be used again after a printer-reset command or at
power ON.
The temporary values can, however, be stored in the flash PROM as permanent values with
command ESC & 4.
Set several parameters at once
ESC & P <000> <FromPar><ParCount><Data>
FromPar is the parameter number to start writing and ParCount is the number of bytes being
sent. For every byte sent the parameter number is incremented.
This command should be used when you integrate firmware loading into your kiosk program.
This command should only be used when loading new firmware into the printer. See also
Firmware on page 113
ESC & P n1...n2
Set Parameter Value
1B 26 50 n1...n2 hex
27 38 80 n1...n2 decimal
n1 Parameter number, range 1 -255.
n2 Parameter value.
Example • This example sets the first 5 tabs to 5, 10, 15, 20, and 25. (FromPar 15, ParCount
5)
<ESC>&P<000><015><005><005><010><015><020><025>«»
ESC NUL
Load Firmware
1B 00 Hex
27 0 Decimal
Note • Utility programs to load firmware into the printer are available from
http://www.zebra.com .