42
Programming
Command Reference
01/06/2009 TTPM3 Installation and Programming Manual P1003642-001
This command sets the resolution of the print. This only affects the resolution in the transport
direction of the ticket.
This command reads out the value of the internal ticket counter from the control board. This
counter starts from 0 when the printer is new and is incremented by one fore each completed
!P sequence.
The result is sent as 12 decimal digits + CR + LF
Reads out the internal retract counter. This counter is incremented by one for each ticket that is
retracted and thrown in the wastebasket.
To reset the counter to zero, send the command !C1.
The result is sent as 12 decimal digits + CR + LF.
!X
Set resolution
21 58 Hex
33 88 Decimal
0 normal resolution, (5.7dots/mm).
1 high resolution (8.5 dots/mm).
!Y
Read ticket counter
21 59 Hex
33 89 Decimal
!Y 1
Read retract counter
21 59 31 Hex
33 89 49 Decimal
Note • Retract function is only available on printers with waste bin option (part of front load
FL3 and FL4).