a = mark sensing (3-digit value)
Accepted Values: 000 to 100
Default Value: The value calculated in the calibration process.
b = mark media sensing (3-digit value)
Accepted Values: 000 to 100
Default Value: The value calculated in the calibration process.
c = mark LED sensing (3-digit value)
Accepted Values: 000 to 100
Default Value: The value calculated in the calibration process.
Example:
In the illustration below is an example of a media sensor profile. Notice the numbers
from 000 to 100 and where the words WEB, MEDIA and RIBBON appear in
relation to those numbers. Also notice the black vertical spike. This represents
where the printer sensed the transition from media-to-web-to-media.
The media and sensor profiles produced will vary in appearance from printer to
printer.
Comments: The m2 and r2 parameters have no effect in Stripe
®
printers.
Maximum values for parameters will depend on which printer platform is being
used.