oM Command - Disable Initial Esc Sequence Feed
Description: This command disables the automatic label cal
-
ibration routine executed by the printer upon
receiving the first command sequence. The
printer normally measures a single label and
sets the top of form prior to printing the first label
after a power-up reset. The Eltron Windows™
printer driver issues escape sequences when
printing.
This command’s primary use is to save
preprinted forms such as serialized labels, tags
or tickets.
Syntax: oM
This command must be issued prior to printing
with the Windows driver’s or any other Escape
(esc) mode printing operation.
To reinitialize label calibration, issue a o (small
letter “o”) command. See page G-9 for impor-
tant details on the effects of using the o com-
mand.