Zebra EPL2 Specifikace Strana 172

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 248
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 171
O Command - Options Select
Description Use this command to select various printer op
-
tions. Options available vary by printer model.
Syntax
O[C[p
1
], D, d, P, L, S]
Parameters d= Replaced by xa command
Disable Diagnostic Dump Mode.
P2242 only - Disables the printer’s
AutoSense Dump Mode Printout. The
setting is stored in nonvolatile memory.
Sending a 0 command without the d
will reset the Dump Mode operation.
S = Reverse the Transmissive (Gap) Sen
-
sor Operation.
This option is designed to allow use of
transparent media and liner with a
opaque mark between labels. The
transmissive (gap) sensor is used to de-
tect this mark which can be on the top or
back side of the transparent liner.
C
= Enable optional Label Liner Cutter.
See Appendix F, page F-E for more details.
See Section 2, page 2-39 for more details on the
following.
D = Enable Direct Thermal Mode.
P = Enable Label Dispense Mode -
Portables
L = Enable Label Dispense Mode - Tap
to Feed.
Examples:
O :disables all options.
OC :enables cutter only, labels are cut after each
:label is printed, disables all other options
OD :enables direct thermal mode on thermal transfer
:printers, disables all other options
Od :disables diagnostic dump mode and disables
:all other options
OCb :labels are cut after a batch of five has printed,
... :disables all other options
P5 :Sets the number of labels to print before the cut
G-8
980009-001 Rev.F
Appendix G - Advanced Programming
Zobrazit stránku 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 247 248

Komentáře k této Příručce

Žádné komentáře