Routine Maintenance
Fuse Replacement
112
13163L-001 Rev. A Z4Mplus/Z6Mplus User Guide 1/18/06
Fuse Replacement
A user-replaceable AC power fuse is located just below the AC power switch at the rear of the
printer. The replacement fuse is a 5 × 20 mm fast-blow style rated at 5 Amp/250 VAC.
Figure 36 • Replacing the Fuse
To replace the fuse, complete these steps:
1. See Figure 36. Insert the tip of a flat blade screwdriver into the slot in the end of the fuse
holder.
2. Turn the screwdriver counterclockwise until the fuse holder disengages from fuse socket.
3. Remove the fuse holder from the fuse socket.
4. Remove the old fuse from the fuse holder.
5. Insert a new, compatible fuse into the fuse holder.
6. Place the fuse holder into the fuse socket.
7. Insert the tip of a flat blade screwdriver into the slot in the end of the fuse holder.
8. With the screwdriver, press in gently, and then turn the screwdriver clockwise until the
fuse holder engages.
Caution • Turn Off (O) the printer and disconnect it from the power source before
performing the following maintenance.