OPERATING THE SCANNER 5 - 21
Press and hold
Scale Zero
button
Click No change None If
Scale Zero
button is enabled,
causes the scale calibration audit
trail to display until button is
released.
Press and
hold
/release
Scale Zero
and
EAS
buttons
Click Red after 10
s
econds upon
reboot
No change After buttons are held for 10
seconds, a system reboot initiates.
NOTE:
The following condition occurs with firmware versions older than 3.4 (see
Identifying Firmware Version on page
4-2
).
Press and hold
Scale Zero
and
Volume/Tone
buttons
Five long beeps after 5
sec
onds
No change No change After five seconds, scale calibration
is entered.
NOTE:
The following condition occurs with firmware version 3.4 and newer (see
Identifying Firmware Version on page
4-2
).
Press and hold
Scale Zero
and
Volume/Tone
buttons for 5
seconds, then
release
Short beep after 5
sec
onds; within 2
seconds of release,
press the
Scale Zero
and
Volume/Tone
again and release; 5
long beeps sound
No change No change After final 5 long beeps sound,
sc
ale calibration is entered.
Press and release
EAS
button
Click No change EAS is enabled,
LE
D is amber
If EAS is enabled, button press
activates tag manual deactivation.
Code 39 Buffering
Code 39
character added
into buffer
High, Low Beeps No change No change New Code 39 data was entered
into the buffer.
Code 39 buffer full 3 Long High Beeps No change No change Code 39 buffer is full.
Code 39 buffer
clea
red
High, Low, High Beeps No change No change The Code 39 buffer was erased.
Code 39 buffer
empty
Low, High, Low Beeps No change No change The Code 39 buffer was erased or
there was an attempt to clear
or
transmit an empty buffer.
Code 39 buffer
transmit
ted
Low, High Beeps No change No change A successful transmission of
buffered data.
EAS/Security Tags
EAS system
disabled
None No change EAS LED is off EAS parameter disabled.
Table 5-1
Beeper and LED Indicators (Continued)
Condition Beeper Indication
System LED
Indication
Button LED
Indication
Description