PA Command - Print Automatic
Description Usethis command inastored formsequenceto
automaticallyprint theform (assoon asall vari
-
able data has been supplied).
Syntax PAp
1
, [p
2
]
Parameters p
1
=Number of label sets. Can be variable
data.
Range: 1 to 9999
p
2
=Number of copies of the same label.
Can be variable data.
Range: 1 to 9999
Sets the number of copies of each label
(used in combination with counters) to
print multiple copies of the same label.
This value is only set when using coun-
ters.
Example:
FK"1" : delete form named “1"
FS"1" : start form store sequence
V00,10,N,"prompt:" : define variable 00
V01,1,N,"prompt:" : define variable 01
V02,4,N,"prompt:" : define variable 02
A24,24,0,4,1,1,N,V00 : write a line of text including variable
PAV01,V02 : print 1 label automatically
FE : end form store sequence
FR"1" : retrieve form “1"
? : get variables
This Is Text¿ : data for V00
3¿ : data for V01= p
1
- number of sets
2¿ : data for V02= p
2
- number of copies
980352-001 Rev.A
3-77