Installation
Installing an OEM Printer Mechanism
12
P1003645-001 TTPM2™ Installation and Programming Manual 03/05/2009
Figure 4 • Dimension drawing for printer mechanism. All measurements are in
mm
The printer mechanism requires +5 Vdc, 0.3 A, and + 24 Vdc 2 A continuous, 6 A peak. This
is fed to the printer through J5 on the control board.
With Zebra power supplies, just connect the cable from the power supply to J5.
If you use another type of power supply, connect the voltages according to the following table.
At the TTPM2 end of the cable, use a Molex 22-01-2065 connector housing and six Molex 08-
50-0032 contact springs. The cable area should be 6 x 0.24mm
2
, and the cable length no more
than 0.5 m. If longer cable is required, a 5 V regulator has to be placed near the printer. The 24
V should feed this regulator.